Omnidirectional capsule head, diffuse field equalized, capsule woodbox, nickel. Compatible with KM A (analog) or KM D (digital) output stages. Nickel finish



The KK 183 is a diffuse-field equalized pressure transducer with a free-field treble boost (approx. 7 dB at 10 kHz). The frequency response in the diffuse sound field is flat up to 10 kHz.
  • Nickel non-reflective finish
  • Omnidirectional Polar Pattern
  • User installable
  • Acoustical operating principle: Pressure transducer
    Directional Pattern: Omni diffuse-field equalized
    Frequency Range: 20 Hz...20 kHz
    Sensitivity at 1 kHz, 0 dB gain, and 94 db SPL: -41 dB FS
    Equivalent noise level, CCIR¹: 25 dB
    Equivalent noise level, A-weighted²: 13 dB-A
    Maximum SPL at 0 dBFS (re. 94 dB SPL): 135 dB SPL
    Maximum SPL with 18 dB preatt. (RCS) (re. 94 dB SPL): 153 dB SPL
    Signal-to-noise ratio, CCIR (re. 94 dB SPL)³: 69 dB
    Signal-to-noise ratio, A-weighted (re. 94 dB SPL): 81 dB
    Matching connector: XLR 3 F
    Weight (output stage): 70 g
    Weight (capsule only): 11 g
    Diameter: 22 mm
    Length (capsule only): 18 mm
    Length (microphone): 108 mm
    A/D conversion: Neumann process (patented), 28-bit internal word length
    Digital signal processing: Fixed-point, variable internal word length 28 bits to 60 bits
    Sampling rates: 44.1/48/88.2/96/176.4/192 kHz
    Output data format: 24 bits as per AES/EBU (AES 3)
    Latency: 44.1/48 kHz: 41 samples
    Latency: 88.2/96 kHz: 49 samples
    Latency: 176.4/192 kHz: 99 samples
    Synchronization: Free-running (non-synchronous operation), frequency stability: ± 25 ppm
    Synchronization: Synchronous operation, pulling range: min. ± 100 ppm
    Supply voltage range: +7 V to +10.5 V
    Current consumption: max. 150 mA (DDP)

    ¹ according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS
    ² according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS
    ³ according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS
    according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS